-40%

Hantek DSO5072P DSO5102P DSO5202P 70MHZ 100MHZ 200MHz 2CH Oscilloscope 1GSa/s

$ 137.27

Availability: 49 in stock
  • All returns accepted: Returns Accepted
  • Bandwidth: DSO5072P 70MHz / DSO5102P 100MHz / DSO5202P 200MHz
  • MPN: Does Not Apply
  • Restocking Fee: No
  • Country/Region of Manufacture: China
  • Maximum Real-Time Sampling Rate: 1 GSa/s
  • Number of Channels: 2
  • Refund will be given as: Money back or replacement (buyer's choice)
  • AC Power: AC 110V-250V
  • Sample Rate: 1GSa/s - 1.9GSa/s
  • Type: Digital Oscilloscope
  • Oscilloscope Type: Digital Oscilloscope
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Channels: 2
  • Digital Oscilloscope Resolution: 8-bit
  • Item must be returned within: 60 Days
  • Brand: Hantek
  • Features: With Probe
  • Model: DSO5072P 70MHz / DSO5102P 100MHz / DSO5202P 200MHz
  • Maximum Bandwidth: 100 MHz
  • Plug: USA/EU/GB/CH

    Description

    DSO5000P Series
    Feature:
    200/100/70MHz bandwidths
    1GSa/s Real Time sample rate
    Large (7.0-inch) color display, WVGA(800x480)
    Record length up to 40K
    Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
    USB host and device connectivity, standard
    Multiple automatic measurements
    Four math functions, including FFTs standard
    Provides software for PC real-time analysis
    Model
    DSO5202P
    DSO5102P
    DSO5072P
    Acquisition
    Sample Rate
    Real-Time Sample: 1GS/s
    Equivalent Sample: 25GS/s
    Acquisition Modes
    Normal
    Normal data only
    Peak Detect
    High-frequency and randon glith capture
    Average
    Wavefom Average, selectable 4,8,16,32,64,128
    Inputs
    Inputs Coupling
    AC, DC, GND
    Inpits Impendance
    1MΩ±2% ‖20pF±3pF
    Probe Attenuation
    1X, 10X
    Supported Probe Attenuation Factor
    1X, 10X, 100X, 1000X
    Maximum Input Voltage
    CAT I and CAT II: 300VRMS (10×), Installation Category;
    CAT III: 150VRMS (1×);
    Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
    Horizontal
    Sample Rate Range
    500MS/s--1GS/s
    Waveform Interpolation
    (sin x)/x
    Record Length
    40K
    SEC/DIV Range
    2ns/div to 40s/div
    4ns/div to 40s/div
    Sample Rate and
    Delay Time Accuracy
    ±50ppm(at over any ≥1ms time interval)
    Position Range
    2ns/div to 10ns/div;
    (-4div x s/div) to 20ms;
    20ns/div to 80us/div; (-8div x s/div) to 40ms;
    200us/div to 40s/div; (-8div x s/div) to 400s
    Delta Time Measurement Accuracy
    (Full Bandwidth)
    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
    >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
    Sample interval = s/div ÷ 200
    Vertical
    Vertical Resolution
    8-bit resolution, all channel sampled simultaneously
    Position Range
    2mV/div to 200mV/div, ±2V
    200mV/div to 5V/div, ±50V
    Bandwidth
    200MHz
    100MHz
    70MHz
    Rise Time at BNC( typical)
    1.8ns
    3.5ns
    5ns
    Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled
    2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V
    500mV/div to 2V/div, ±40V; 5V/div, ±50V
    Math
    +, -, *, /, FFT
    FFT
    Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
    1024 sample point
    Bandwidth Limit
    20MHz
    Low Frequency Response (-3db)
    ≤10Hz at BNC
    DC Gain Accuracy
    ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
    ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
    DC Measurement Accuracy,
    Average Acquisition Mode
    When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
    When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
    Volts Measurement Repeatability,
    Average Acquisition Mode
    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
    Trigger System
    Trigger Types
    Edge, Video, Pulse, Slope, Over time, Alternative
    Trigger Source
    CH1, CH2, EXT, EXT/5, AC Line
    Trigger Modes
    Auto, Normal, Single
    Coupling Type
    DC, AC, Noise Reject, HF Reject, LF Reject
    Trigger Sensitivity
    (Edge Trigger Type)
    DC(CH1,CH2):
    1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
    DC(EXT):
    200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
    DC(EXT/5):
    1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
    AC: Attenuates signals below 10Hz;
    HF Reject: Attenuates signals above 80kHz;
    LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
    Trigger Level Range
    CH1/CH2: ±8 divisions from center of screen;
    EXT: ±1.2V;
    EXT/5:±6V
    Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
    CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
    EXT: ± (6% of setting + 40mV);
    EXT/5: ± (6% of setting + 200mV);
    Set Level to 50%(typical)
    Operates with input signals ≥50Hz
    Video Trigger
    Video Trigger Type
    CH1, CH2: Peak-to-peak amplitude of 2 divisions;
    EXT: 400mV;
    EXT/5: 2V
    Signal Formats and Field Rates, Video Trigger Type
    Supports NTSC, PAL and SECAM broadcast systems for any field or any line
    Holdoff Range
    100ns ~ 10s
    Pulse Width Trigger
    Pulse Width Trigger Mode
    Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
    Pulse Width Trigger Point
    Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
    Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
    Less than: The trigger point is the trailing edge.
    Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
    Pulse Width Range
    20ns ~ 10s
    Slope Trigger
    Slope Trigger Mode
    Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
    Slope Trigger Point
    Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
    Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
    Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
    Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
    Time Range
    20ns ~ 10s
    Overtime Trigger
    Over Time Mode
    Rising edge or Falling edge
    Time Range
    20ns ~ 10s
    Alternative Trigger
    Trigger on CH1
    Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger on CH2
    Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger Frequency Counter
    Readout Resolution
    6 digits
    Accuracy (typical)
    ±30ppm (including all frequency reference errors and ±1 count errors)
    Frequency Range
    AC coupled, from 4Hz minimum to rated bandwidth
    Signal Source
    Pulse Width or Edge Trigger modes: all available trigger sources
    The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
    Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
    Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
    Video Trigger mode: The Frequency Counter does not work.
    Measure
    Cursor Measurement
    Voltage difference between cursors: △V
    Time difference between cursors: △T
    Reciprocal of △T in Hertz (1/ΔT)
    Auto Measuerment
    Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
    Display
    Display Type
    7 inch 64K color TFT (diagonal liquid crystal)
    Display Resolution
    800 horizontal by 480 vertical pixels
    Display Contrast
    Adjustable (16 gears) with the progress bar
    Probe Compensator Output
    Output Voltage( typical)
    About 5Vpp into ≥1MΩ load
    Frequency(typical)
    1kHz
    Power Supply
    Supply Voltage
    100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
    120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
    Power Consumption
    <30W
    Fuse
    2A, T rating, 250V
    Environmental
    Temperature
    Operating: 32℉ to 122℉ (0℃ to 50℃);
    Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
    Cooling Method
    Convection
    Humidity
    +104℉ or below (+40℃ or below): ≤90% relative humidity;
    106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
    Altitude
    Operating: Below 3,000m (10,000 feet);
    Nonoperaring: Below 15,000m(50,000 feet)
    Mechanical
    Size
    Length 385mm, Width 200mm, Height 245mm
    Weight
    3.5KG(with Packing); 2.08KG(without Packing)