-40%

Hantek DSO8072E 6 in 1 Oscilloscope Recorder DMM Spectrum Analyzer Frequency

$ 300.95

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Condition: New
  • Maximum Bandwidth: 70 MHz
  • MPN: DSO8072E
  • Country/Region of Manufacture: China
  • Model: Oscilloscope
  • Modified Item: No
  • Sample Rate: 1GSa/s
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 60 Days
  • Digital Oscilloscope Resolution: 8-bit
  • Maximum Real-Time Sampling Rate: 1 GSa/s
  • Oscilloscope Type: Digital Storage Oscilloscope (DSO)
  • Brand: HANTEK
  • Number of Channels: 2
  • Channels: 2
  • Country of Manufacture: China
  • Type: Digital
  • Make: Hantek
  • Features: Handheld/ Portable
  • All returns accepted: Returns Accepted
  • Bandwidth: 70Mhz

    Description

    Features
    :
    Six in one: Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbitrary Waveform generator.
    IP-51 rated for dust, drip and shake proof to withstand harsh environments.
    Large fuse confirms to European Safety Standard.
    Battery indicator with easy-changed connect points. Selectable 18650 battery box for matching 18650 battery by yourself.
    Anti-theft lock hole, tripod fixed hole, hang rope, FLASH light that can be used in darkness.
    Replaceable BNC safety joints, and additional one set of joints.
    High bandwidth 70MHz-200MHz Oscilloscope, 1GSa/s sample rate, 2M Memory depth.
    25Mz Arb. Waveform Generator, 200 Mesa/s DDS, 12 bit vertical resolution, easy for simulating transducer
    6000 Counts DMM, AC/DC voltage, AC/DC current, resistance, break, capacitance, and diode function.
    FFT  spectral analysis; Waveform Math: add, subtract, multiply and divide;  X-Y mode; more than 20 automatic measurements; PASS/FAIL Check function,  apply to engineering application.
    Abundant trigger function, double timebase sampling, easy to observe two waveforms in different frequency.
    Record and replay of more than 1000 waveforms.
    Large 5.6 inch TFT Color LCD Display; High Resolution(640*480)
    USB Host/Device 2.0 full-speed interface; support removable disk; WIFI/LAN Option, easy to control by PC or long-distance.
    Waveform data can be output in WORD,EXCEL, BMP, JPG as time and voltage.
    Characteristic:
    Model
    DSO8072E
    DSO8102E
    DSO8152E
    DSO8202E
    Acquisition
    Sample Modes
    Real-Time Sample
    Acquisition Modes
    Normal
    Normal data only
    Peak Detect
    High-frequency and randon glith capture
    Average
    Wavefom Average, selectable 4,8,16,32,64,128
    Inputs
    Inputs Coupling
    AC, DC, GND
    Inputs Impendance
    1MΩ±2% ‖20pF±3pF
    Probe Attenuation
    1X, 10X
    Supported Probe Attenuation Factor
    1X, 10X, 100X, 1000X
    Maximum Input Voltage
    CAT I and CAT II: 300VRMS (10×), Installation Category;
    CAT III: 150VRMS (1×)
    Horizontal System
    Sample Rate Range
    1GS/s
    Waveform Interpolation
    (sin x)/x
    Record Length
    2M
    SEC/DIV Range
    4ns/div~2000s/div, in a 2, 4, 8 sequence
    2ns/div~2000s/div, in a 2, 4, 8 sequence
    Sample Rate and
    Delay Time Accuracy
    ±50ppm over any ≥1ms time interval
    Scanning Speed Range
    4ns/div to 8ns/div; (-8div x s/div) to 40ms;
    20ns/div to 80μs/div;(-8div×s/div) to 40ms;
    200μs/div to 40s/div;(-8div×s/div) to 400s;
    2ns/div to10ns/div;(-4div×s/div) to 20ms;
    Delta Time Measurement Accuracy
    (Full Bandwidth)
    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
    >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
    Sample interval = s/div ÷ 200
    Vertical System
    Vertical Resolution
    8-bit resolution, all channel sampled simultaneously
    Volts Range
    2mV/div to 100V/div at input BNC
    Bandwidth
    70MHz
    100MHz
    150MHz
    200MHz
    Rise Time at BNC( typical)
    5ns
    3.5ns
    2.3ns
    1.8ns
    Analog Bandwidth in
    Normal and Average
    modes at BNC or with probe,
    DC Coupled
    ±400V(100V/div-20V/div);
    ±50V(10V/div-5V/div);
    ±40V(2V/div-500mV/div);
    ±2V(200mV/div-50mV/div);
    ±400mV(20mV/div-2mV/div);
    Math
    +, -, *, /, FFT
    FFT
    Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
    Bandwidth Limit
    20MHz
    Low Frequency Response (-3db)
    ≤10Hz at BNC
    DC Gain Accuracy
    ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.
    ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
    DC Measurement Accuracy,
    Average Acquisition Mode
    Measurement Type: Average of ≥16 waveforms with vertical position at zero
    Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.
    Measurement Type: Average of ≥16 waveforms with vertical position not at zero
    Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].
    Volts Measurement Repeatability,
    Average Acquisition Mode
    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
    Trigger System
    Trigger Types
    Edge, Video, Pulse, Slope, Over time, Alternative
    Trigger Source
    CH1, CH2, AC Line
    Trigger Modes
    Auto, Normal, Single
    Coupling Type
    DC, AC, HF Reject, LF Reject, Noise Reject
    Trigger Sensitivity
    (Edge Trigger Type)
    DC(CH1,CH2):
    1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
    AC: Attenuates signals below 10Hz ;
    HF Reject: Attenuates signals above 80kHz;
    LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.
    Trigger Level Range
    CH1/CH2: ±8 divisions from center of screen;
    Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
    CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
    Set Level to 50%(typical)
    Operates with input signals ≥50Hz
    Video Trigger
    Video Trigger Type
    CH1, CH2: Peak-to-peak amplitude of 2 divisions;
    Signal Formats and Field Rates
    Supports NTSC, PAL and SECAM broadcast systems for any field or any line
    Holdoff Range
    100ns ~ 10s
    Pulse Width Trigger
    Pulse Width Trigger Mode
    Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
    Pulse Width Trigger Point
    Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
    Not  Equal: If the pulse is narrower than the specified width, the trigger  point is the trailing edge. Otherwise, the oscilloscope triggers when a  pulse continues longer than the time specified as the Pulse Width.
    Less than: The trigger point is the trailing edge.
    Greater  than (also called overtime trigger): The oscilloscope triggers when a  pulse continues longer than the time specified as the Pulse Width
    Pulse Width Range
    20ns ~ 10s
    Slope Trigger
    Slope Trigger Mode
    Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
    Slope Trigger Point
    Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
    Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
    Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
    Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
    Time Range
    20ns ~ 10s
    Overtime Trigger
    Over Time Modee
    Rising edge or Falling edge
    Time Range
    20ns ~ 10s
    Alternative Trigger
    Trigger on CH1
    Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger on CH2
    Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger Frequency Counter
    Readout Resolution
    6 digits
    Accuracy (typical)
    ±30ppm (including all frequency reference errors and ±1 count errors)
    Frequency Range
    AC coupled, from 4Hz minimum to rated bandwidth
    Signal Source
    Pulse Width or Edge Trigger modes: all available trigger sources
    The  Frequency Counter measures trigger source at all times, including when  the oscilloscope acquisition pauses due to changes in the run status, or  acquisition of a single shot event has completed.
    Pulse Width  Trigger mode: The oscilloscope counts pulses of significant magnitude  inside the 1s measurement window that qualify as triggerable events,  such as narrow pulses in a PWM pulse train if set to < mode and the  width is set to a relatively small time.
    Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
    Video Trigger mode: The Frequency Counter does not work.
    Measure
    Cursor Measurement
    Manual: Voltage difference between cursors: △V
    Time difference between cursors: △T
    Reciprocal of △T in Hertz (1/ΔT);
    Tracing: The valtage and time at a waveform point;
    Auto Measuerment
    Frequency,  Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,  +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty,  Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
    Waveform Generator Mode
    Frenquency Range
    1Hz(DC)~25MHz
    DAC Clock
    2K~200MHz adjustable
    Memory Depth
    4KSa
    Vertical Resolution
    12 Bits
    Stability
    <30ppm
    Amplitude
    ±3.5V Max.
    Output Impedance
    50 Ω
    Output Current
    50mA Ipeak=50mA
    System Bandwidth
    25M
    Harmonic Wave Distortion
    -50dBc(1KHz), -40dBc(10KHz)
    General Specifications
    Display Resolution
    640 horizontal by 480 vertical pixels
    Display Contrast
    Adjustable (16 gears) with the progress bar
    Probe Compensator Output
    Output Voltage( typical)
    About 2Vpp into ≥1MΩ load
    Frequency(typical)
    1kHz
    Power Supply
    Supply Voltage
    AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A
    Power Consumption
    <30W
    Environmental
    Temperature
    Operating: 32℉ to 122℉ (0℃ to 50℃);
    Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
    Cooling Method
    Convection
    Humidity
    +104℉ or below (+40℃ or below): ≤90% relative humidity;
    106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
    Altitude
    Operating: Below 3,000m (10,000 feet);
    Nonoperaring: Below 15,000m(50,000 feet)
    Mechanical
    Size
    260mmmm; 220mm; 75mm
    Weight
    2.5KG(without Packing)
    DMM Mode
    Max. Resolution
    6000 Counts
    DMM Testing Modes
    Voltage, Current, Resistance, Capacitance, Diode & Continuity
    Max. Input Voltage
    AC:600V, DC: 800V
    Max. Input Current
    AC: 10A, DC:10A
    Input Impedance
    10MΩ
    DMM TrendPlot
    1.2M Point
    Range
    Resolution
    Accuracy
    Resolution
    DC Voltage
    60.00mV
    ±1%±3 digit
    10uV
    600.0mV
    100uV
    6.000V
    1mV
    60.00V
    10mV
    600.0V
    100mV
    800V
    1V
    AC Voltage
    60.00mV
    ±1%±3 digit
    10uV
    600.0mV
    100uV
    6.000V
    1mV
    60.00V
    10mV
    600.0V
    100mV
    DC Current
    60.00mA
    ±1%±5 digit
    10uA
    600.0mA
    ±1.5%±5 digit
    100uA
    6.000A
    1mA
    10.00A
    10mA
    AC Current
    60.00mA
    ±1%±5 digit
    10uA
    600.0mA
    ±1.5%±5 digit
    100uA
    6.000A
    1mA
    10.00A
    10mA
    Resistance
    600Ω
    ±1%±3 digit
    0.1Ω
    6.000KΩ

    60.00KΩ
    10Ω
    600.0KΩ
    1KΩ
    6.000MΩ
    10KΩ
    60.00MΩ
    ±1%±5 digit
    100KΩ
    Capacitance
    40.00nF
    ±2%±5 digit
    10pF
    400.0nF
    100pF
    4.000uF
    1nF
    40.00uF
    10nF
    400.0uF
    100nF
    Attention: the smallest capacitance value that can be measured in 5nF
    Diode
    0V~2.0V
    ON-OFF test
    <10Ω
    Package (gift box):
    1 x 8072E oscilloscope
    2 x oscilloscope probe
    1 x USB cable
    2 x test probe
    1 x power cable
    1 x CD (Manual etc.)