  • Maximum Real-Time Sampling Rate: 4 GSa/s
  • Digital Oscilloscope Resolution: 8-bit
  • Brand: LeCroy
  • Maximum Bandwidth: 750 MHz
  • Restocking Fee: No
  • MPN: WAVESURFER3074
  • Condition: Used
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money Back
  • Oscilloscope Type: Digital Oscilloscope
  • All returns accepted: Returns Accepted
  • Number of Channels: 4
  • Item must be returned within: 30 Days
  • Model: WAVESURFER 3074

    Description

    This unit has the following options: AFG, DVM
    Features:
    Analog-Vertical
    Bandwidth (@ 50Ω): 7500 MHz
    Rise time: 550 ps typical
    Vertical Resolution: 8-bits; up to 11-bits with enhanced resolution (ERES)
    Sensitivity: 50 Ω: 1mV/div - 1 V/div; 1 MΩ: 1 mV/div - 10 V/div
    DC Gain Accuracy: ± (1.5%) Full Scale, Offset at 0V, > 5mV/div; ± (2.5%) < 5 mV/div
    BW Limit 20 MHz, 200 MHz
    Maximum Input Voltage: 50 Ω: 5 Vrms, ±10 V Peak; 1 MΩ: 400 V max (DC + Peak AC ≤ 10 kHz)
    Input Coupling: 50 Ω: DC, GND; 1 MΩ: AC, DC, GND
    Input Impedance: 50 Ω ±2.0%, 1 MΩ ±2.0% || 16 pF
    Offset Accuracy: ± (1.0% of offset value + 1.5%FS + 1 mV)
    Long Memory – up to 10 Mpts/Ch
    10.1” touch screen display
    MAUI Advanced User Interface
    Designed for Touch
    Built for Simplicity
    Made to Solve
    Advanced Anomaly Detection
    Fast Waveform Update
    History Mode
    WaveScan
    Capture, Debug, Analyze, Document
    LabNotebook
    Sequence Mode
    Advanced Active Probe Interface
    Math and Measure
    Multi-Instrument Capabilities
    Protocol Analysis
    Serial
    Trigger and Decode
    Analog - Acquisition
    Sample Rate (Single-shot): 2 GS/s (4 GS/s interleaved)
    Sample Rate (Repetitive): 50 GS/s
    Record Length: 10 Mpts/ch (all channels)
    Acquisition Modes: Real Time, Roll, RIS (Random Interleaved Sampling), Sequence (Segmented Memory up to 1,000 segments with 1μs minimum intersegment time)
    Real Time Timebase Range: 1 ns/div - 50 s/div
    RIS Mode Timebase Range: 1 ns/div - 10 ns/div
    Roll Mode Timebase Range: Up to 50 s/div (roll mode is user selectable at ≥ 50 ms/div)
    Timebase Accuracy: ±10 ppm measured over > 1ms interval
    Trigger System
    Modes: Auto, Normal, Single, Stop
    Sources: Any input channel, External, Ext/5, or line; slope and level unique to each source (except for line trigger)
    Coupling: DC, AC, HFREJ, LFREJ
    Pre-trigger Delay: 0-100% of full scale
    Post-trigger Delay: 0-10,000 Divisions
    Hold-off 10ns up to 20s or 1 to 100,000,000 events
    Internal Trigger Level Range: ±4.1 Divisions
    External Trigger Level Range: Ext: ±610mV, Ext/5: ±3.05V
    Trigger Types: Edge, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV - 720p, 1080i, 1080p), Runt, Slew Rate, Interval (Signal or Pattern), Dropout, Qualified (State or Edge); External and Ext/5 support edge trigger only.
    Measure, Zoom and Math Tools
    Measurement Parameters: Up to 6 of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base, Delay, Duty Cycle, Fall Time (90%–10%), Fall Time (80%–20%), Frequency, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Peak-Peak, Period, Phase, Rise Time (10%–90%), Rise Time (20%–80%), RMS, Skew, Standard Deviation, Top, Width+, Width-. Statistics and histicons can be added to measurements. Measurements can be gated.
    Zooming: Use front panel QuickZoom button, or use touch screen or mouse to draw a box around the zoom area.
    Math Functions: Up to 2 of the following functions can be calculated at one time: Sum, Difference, Product, Ratio, Absolute Value, Average, Derivative, Enhanced Resolution, Envelope, Floor, Integral, Invert, Reciprocal, Rescale, Roof, SinX/x, Square, Square Root, Trend, Zoom and FFT (up to 1 Mpts with power spectrum output and rectangular, VonHann, and FlatTop windows).
    Display System
    Display Size 10.1” Wide TFT-LCD Touch-Screen
    Display Resolution: 1024 x 600
    Connectivity
    Ethernet Port: 10/100Base-T Ethernet interface (RJ-45 connector)
    Removable Storage: (1) MicroSD Port - 8 GB micro SD card installed standard
    USB Host Ports: (4) USB Ports Total – (2) Front USB Ports
    USB Device Port: (1) USBTMC
    GPIB Port (Optional): Supports IEEE – 488.2
    External Monitor Port: Standard DB-15 connector (support resolution of 1024x600)
    Remote Control: Via Windows Automation, or via Teledyne LeCroy Remote Command Set
    Network Communication Standard: GPIB IEEE-488.2 and VICP, USBTMC/USB488
    Power Requirements
    Voltage: 100 - 240 VAC ± 10% at 50-60 Hz +/-5%; 100 - 120 VAC ± 10% at 400 Hz +/- 5%; Automatic AC Voltage Selection
    Power Consumption (Nominal): 100 W / 100 VA
    Power Consumption (Max): 150 W / 150 VA (with all PC peripherals, digital leadset and active probes connected to 4 channels)
    Environmental
    Temperature Operating: 0 °C to 50 °C; Non-Operating: -30 °C to 70 °C
    Humidity Operating: 5% to 90% relative humidity (non-condensing) up to ≤ 30 °C, Upper limit derates to 50% relative humidity (non-condensing) at +50 °C
    Non-Operating: 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
    Altitude Operating: 3,048 m (10,000 ft) max at ≤ 25C; Non-Operating: Up to 12,192 meters (40,000 ft)
    Physical
    Dimensions (HWD) 10.63” H x 14.96” W x 4.92” D (270 mm x 380 mm x 125 mm)
    Regulatory
    CE Certification Low Voltage Directive 2006/95/EC; EN 61010-1:2010, EN 61010-2-030:2010
    EMC Directive 2004/108/EC; EN 61326-1:2013, EN61326-2-1:2013; RoHS2 Directive 2011/65/EU
    UL and cUL Listing UL 61010-1, UL 61010-2-030:2010, 3rd Edition; CAN/CSA C22.2 No. 61010-1-12
    MAUI-A New Wave of Thinking
    MAUI is the most advanced oscilloscope user interface. MAUI is designed for touch; all important oscilloscope controls are accessed through the intuitive touch screen. MAUI is built for simplicity; time saving shortcuts and intuitive dialogs simplify setup. MAUI is made to solve; deep set of debug and analysis tools help identify problems and find solutions quickly.
    Advanced Anomaly Detection
    Combining a fast waveform update rate of 130,000 waveforms/second with History mode waveform playback and WaveScan search and find, the WaveSurfer 3000 is an outstanding tool for waveform anomaly detection.
    Capture, Debug, Analyze, Document
    The advanced active probe interface gives tremendous flexibility for capturing all types of signals. Debug, analyze and document problems through the use of powerful math and measurement capabilities, sequence mode segmented memory, and LabNotebook.
    Combining a fast waveform update rate of 130,000 waveforms/second with History mode waveform playback, Pass/Fail Mask Testing and WaveScan search and find, the WaveSurfer 3000 is an outstanding tool for waveform anomaly detection. A powerful set of triggering capabilities ensures that once a problem is detected it can be isolated and analyzed.
    WaveScan Advanced Search
    Locate unusual events in a single capture or scan for an anomaly across many acquisitions over a long period of time. WaveScan provides powerful isolation capabilities that hardware triggers cannot provide.
    Select from more than 20 search modes to find events on any analog or digital channel. Since the scanning modes are not simply copies of the hardware triggers, the utility and capability is much higher. There is no frequency trigger in any oscilloscope, yet WaveScan allows for frequency to be quickly scanned, notifying the user upon a shift in frequency. Searching can be done based on measured waveform parameters, runts, and non-monotonic edges as well as digital patterns.
    WaveScan quickly and efficiently scans millions of events looking for unusual occurrences. Search and scan results can be seen with annotations directly on the waveform or in the interactive table. Quickly zoom to an event to see more details by simply touching it in the table.
    Pass/Fail Mask Testing
    Built-in pass/fail mask testing quickly identifies problems and marks the location. A history of the pass/fail results can be displayed on the screen.
    There are four different conditions that can be selected to specify a passing condition: All In, All Out, Any In, and Any Out. When a failure is found, one or more of the following actions can be selected to be performed to record the results: save a waveform, stop the acquisition, output and audible alarm, pulse the aux output port, save a hardcopy or even save a LabNotebook entry.
    When the acquisition is running, failures are displayed as a red trace, however when the acquisition is stopped, a failure indicator is displayed to clearly show all failing points. Masks can either be created using the offline mask maker utility or created based on a reference waveform and specifying horizontal and vertical deltas.
    GUARANTEED QUALITY
    Payment Terms
    We accept payment prior to shipping
    Domestic
    :
    Payment methods accepted:
    PayPal - Preferred
    Illinois buyers pay appropriate sales tax based on county (Please contact ValueTronics before making payment).
    International
    :
    Payment methods accepted:
    PayPal
    All international buyers must request an invoice via email from ValueTronics to include shipping costs before finalizing purchase.
    Return Policy
    ValueTronics honors the buyer’s right of refusal for 14 days from receipt.
    Buyer pays return shipping/packaging of all returns (Domestic and International).
    Refund is credited to buyer’s account upon verification of unit’s condition.
    Returns must be shipped with all original accessories. We will not accept any items with obvious signs of additional wear and tear or internal component alterations. All of our items will ship with “Warranty Void” tamper resistant stickers. If any stickers have been removed or tampered with your refund will be cancelled.
    If you need to return your purchase please contact ValueTronics for a RMA.
    Shipping & Handling
    Domestic:
    Varies by listing
    (Includes Insurance)
    All buyers in the continental United States pay a flat rate or determined rate for larger items. Contact us for freight charges where not listed. Insurance is mandatory and included on all shipments.Other shipping methods are available at the request and expense of the buyer.
    International:
    Buyer pays all shipping costs.
    Buyer must request invoice that includes shipping costs before finalizing sale on eBay.
    Shipping insurance is mandatory on all overseas orders.Your phone number is required for shipping purposes so please provide your phone number with all correspondence.
    Estimated Delivery
    : We can usually ship orders within 5 business days of payment receipt. If we can not meet this expectation you will be promptly notified. Many items can be shipped same day. Contact us for more information.
    Shipping
    : All items are professionally packed to arrive undamaged. If a purchase is received in damaged condition, you must immediately file a claim with the freight carrier and report the same to us. All packaging materials must be saved for inspection by the carrier representatives.
    Feedback
    We pride ourselves on exceptional customer service. With 28 years experience in the industry we proudly extend that expertise to our customers.We respond quickly to all comments and concerns with urgency and professionalism.
    We ask that if you have any problems with your purchase, please try to resolve it with us directly before leaving us a
    Neutral
    or
    Negative
    rating on eBay. We have built a sterling reputation based on highly satisfied customers.
    If you do leave us negative feedback before attempting to resolve the problem with us directly, we reserve the right to deem that as final resolution to that matter and will not accept a return or issue a refund.